Product Details:
|
Application: | Moringa Leaves | Warranty: | 1 Year |
---|---|---|---|
Name: | Tunnel - Type Large Capacity Microwave Moringa Leaves Sterilization Machine | After-sales Service Provided: | Field Installation |
Function: | Moringa Leaves Sterillization Machine | Material: | Stainless Steel |
Power: | 3~300KW | Voltage: | 380V |
High Light: | microwave heating system,industrial microwave drying machine |
Tunnel - type Large Capacity Microwave Moringa Leaves Sterilization Machine
Product description
Microwave sterilization equipment adopts special water-cooled magnetron and industrial high-voltage transformer, which is beneficial to long-term stable operation; microwave reaction chamber adopts multi-box optimization design, good heating uniformity, microwave leakage is lower than national standard; control part adopts plc touch screen, monitoring The equipment works, the operation is simple, the work is stable, and the anti-interference ability is very strong; through the large-screen touch screen, the belt speed, microwave power, the working state of each magnetron, the cooling water state of the furnace door, the internal temperature of the furnace chamber can be controlled and displayed. . The microwave sterilization equipment is made of high quality stainless steel material, and the technical parameters of the equipment can be designed according to user requirements to meet the needs of different production scales of users.
Advantage
1. Fast drying speed and short drying time
2. High product quality
3. Short time and fast speed
4. Low temperature sterilization can guarantee food quality
5. Sterilization throughly
Working principle:
1. Microwave sterilization equipment has short time and high speed. Conventional thermal sterilization is to transfer heat from the surface of the food to the inside through heat conduction, convection or radiation. It takes a long time to reach the sterilization temperature. Microwave sterilization is a direct interaction between microwave energy and microorganisms such as food and bacteria. The thermal effect and non-thermal effect work together to achieve the purpose of rapid temperature sterilization. The treatment time is greatly shortened, and the sterilization effect of various materials is generally 3-5 minutes.
2, microwave sterilization equipment low temperature sterilization to maintain nutrients and traditional flavor microwave sterilization is through special thermal and non-thermal effect sterilization, compared with conventional thermal sterilization, can achieve the required disinfection effect at lower temperatures and shorter time .
3, microwave sterilization equipment uniform and thorough conventional thermal sterilization is started from the surface of the material, but through the heat conduction to the inside, there is a temperature difference between the inside and outside. In order to maintain the flavor of the food, the processing time is shortened. Often, the food does not reach a sufficient temperature inside to affect the sterilization effect. Since the microwave has a penetrating effect, when the food is processed as a whole, the surface and the interior are simultaneously acted upon, so the sterilization is uniform and thorough.
4, microwave sterilization equipment is easy to control microwave dry sterilization treatment, the equipment can be used immediately, without the thermal inertia of conventional thermal sterilization, flexible operation, microwave power adjustable, transmission speed continuously adjustable from zero, easy to operate.
Equipment Parameters
|
Sample
Detail
Packing
1. Daub coal oil on the surface of the machines.
2. Plastic film as the inner packing.
3.Train, ship or depend on clients' requirement
Our Service
Before sale services:
1.Provide the free consultation of the equipment
2.Provide the standard device and the flow chart
3. According to the client’s special requirement, offering the reasonable plan and free design helping to select the equipment.
After sale services:
1. Oversea install and debug the equipment.
2. Train the first-line operator.
3. Operation/ Service/ Maintenance Manual: Provided In English.
4. We will provide 1-2 engineer to the client's factory for the installation and teach your workers.
FAQ
1:How big is the power of you machine?
A:We design the power of the machine based on the characteristics of the material you plan to process
2:How is the quality of you prodects?
A:Our products are certificated with CE quallity inspection
3:What's the difference between microwave dryeer and normal dryer?
A:Microwave process is more efficiency and evenly
4:What's you after sale service?
A:We will dispath our engineer to your factory to guide you installation,commissioning and worker taining
5.How is the payment?
Answer: 40% TT as downpayment, 60% TT or L/C before shippment. Before shippment,welcome to inspect the machine
Contact us
Andy Ren
Mob : +86 135 7315 9585 (whatsapp ,wechat all available)
E-mail : info@joyangmachine.com
Contact Person: info
Tel: +8613573159585